WebNov 16, 2024 · 2009 IRC Rebar in Footings Most cities in Oklahoma the inspectors are requiring four #4 horizontal rebars in the footing, or two #5 stacked. I find that no rebar is required in the 2009 IRC except that foundation with stemwall one 12 inches from top of stemwall and one within 3 or 4 inches of bottom of footing... WebFootings are level, or stepped, if the ground slopes more than 1 foot in 10 feet (10%). (R403.1.5) There is minimum 1 inch clear spacing between parallel reinforcing bars. (ACI 318 25.2.2) Footings project beyond the face of the foundation wall at least 2 inches, but not more than the thickness of the footing. (R403.1.1.)
INSPECTION CHECKLIST Residential Footing and …
WebFootings are level or stepped if the ground slopes more than 1 foot in 10 feet. (R403.1.5) Minimum 1” clear spacing between parallel reinforcing bars. (ACI 318 25.2.2) Footings project beyond the face of the foundation wall at least 2 inches, but not more than the thickness of the footing. (R403.1.1.) Footings don’t bear on frozen soil ... WebCode: IRC–12/13 ... R403.1.3 Seismic reinforcing Footing and stem wall reinforcing in Seismic Design Categories D0, D1 and D2 . Concrete footings located in Seismic Design Categories D0, D1 and D2, as established in Table R301.2(1), shall have minimum reinforcement in accordance with this section. Bottom simpson pressure washer extended wand
2024 INTERNATIONAL RESIDENTIAL CODE (IRC) ICC …
http://www.mybuildingpermit.com/sites/default/files/documentation/Footing%20and%20Foundation_0.pdf WebR403.1.7.2 Footing setback from descending slope surfaces. Footings on or adjacent to slope surfaces shall be founded in material with an embedment and setback from the … WebOct 8, 2012 · Aug 12, 2012. #1. Most cities in Oklahoma the inspectors are requiring four #4 horizontal rebars in the footing, or two #5 stacked. I find that no rebar is required in the 2009 IRC except that foundation with stemwall one 12 inches from top of stemwall and one within 3 or 4 inches of bottom of footing (R403.1.3.1). No siesmic requirements here. simpson pressure washer honda gc190